What Is the Difference Between a CSP and Conventional Transformer

Current sense probes (CSPs) and conventional transformers are both used for measuring currents in electrical systems. However, there are fundamental differences between these two devices in terms of operating principles and performance characteristics.

Transformer

What Is CSP

A current sense probe (CSP) is a specialized measuring device that converts current to voltage, enabling the current to be safely and accurately measured with an oscilloscope. CSPs utilize the Hall effect, where a current flowing through a conductor generates a voltage across it when a magnetic field is applied perpendicular to the current flow. The Hall voltage produced is directly proportional to the current being measured. CSPs contain a Hall effect sensor, signal conditioning circuitry, and a current carrying conductor. They provide galvanic isolation between the circuit being measured and the measurement device.

What Is Conventional Transformer

A conventional transformer is a passive electrical device that transfers electrical energy from one circuit to another through electromagnetic induction. It consists of two or more coils of insulated wire wound around a magnetic core. When an alternating current flows through the primary winding, it generates a magnetic flux in the core which induces a voltage in the secondary winding. Conventional transformers are used to increase or decrease AC voltages and currents and provide electrical isolation between circuits.

Difference Between a CSP and Conventional Transformer

While CSPs and conventional transformers both provide isolation and enable current measurements, they have several key differences:

Protection Features

CSPs offer enhanced protection compared to conventional transformers. They utilize a low impedance shunt as the current carrying conductor, which remains at a low voltage even with high currents. This limits the maximum voltage present for operator safety. CSPs also have a larger maximum current rating for both continuous and pulsed currents.

Conventional transformers have a high insertion impedance. With high currents, this can result in a dangerously high voltage on the primary side, posing an electrocution risk. Their current ratings are also lower than CSPs.

Efficiency

CSPs have lower insertion losses compared to conventional transformers, especially at high frequencies. The insertion impedance of a CSP is lower and remains constant over a wider frequency range.

Conventional transformers have higher insertion losses that increase with frequency due to effects like winding resistance, leakage inductance and capacitance. The high impedance also consumes more power.

Size

CSPs have a more compact size compared to conventional transformers with similar current ratings. The smaller size is enabled by the use of a Hall effect sensor which takes up less space than transformer windings.

Conventional transformers require a larger magnetic core and bulkier windings to support the same maximum current as a CSP. The transformer construction also requires more surrounding space for insulation.

Weight

The smaller size of CSPs also translates to lighter weight, making them more portable and easier to use in constrained spaces. A CSP can weigh 5-10 times less than a conventional transformer with an equivalent current rating.

Conventional transformers, with their larger cores and windings, have a substantially higher weight especially at higher current ranges. This makes them more cumbersome for portable applications.

Power Density

CSPs achieve a higher power density (ratio of power output to device volume) due to their compact Hall effect-based design. They can support higher continuous and peak currents relative to their size.

Conventional transformers have a lower power density as a result of the limitations of their coil and magnetic core construction. The required core volume increases substantially to enable higher power transfer.

Response Time

CSPs have a faster response time and can accurately capture rapidly changing currents across a wide frequency range, from DC to several MHz. The Hall effect sensor and output electronics have a high bandwidth.

Conventional transformers have a slower response and are limited to AC current measurements. Their ability to track high frequency current changes is restricted by factors like winding inductance and capacitance.

Cost

CSPs tend to have a higher component and manufacturing cost compared to conventional transformers, especially at lower current ranges. The Hall effect sensor and signal conditioning electronics add to the cost.

Conventional transformers can be lower cost for general purpose applications that don’t require the performance advantages of CSPs. Their construction is simpler, using just wire coils and a magnetic core.

Applications

CSPs excel at measuring dynamic currents over a wide frequency range in demanding applications such as:

  • Power electronics testing and analysis
  • Pulsed current measurements
  • Examining transient phenomena
  • EMC/EMI testing
  • High power circuit characterization

Conventional transformers are suitable for applications like:

  • General purpose AC current measurements
  • Electrical power distribution and isolation
  • Appliance and equipment power supplies
  • Voltage step-up/step-down