What Is 3 Phase Open Delta

In the realm of electrical power distribution, the 3 phase open delta connection offers a unique approach to transformer configuration. This configuration, characterized by its distinct arrangement of transformers, finds applications across various industrial and commercial settings.

The 3 phase open delta connection brings forth a set of features and advantages that make it an attractive choice in specific scenarios. However, it also comes with certain limitations that must be considered. In the following sections, we will delve into the intricacies of the 3 phase open delta connection, exploring its working principles, features, applications, advantages, and disadvantages.

step down transformers

What Is 3 Phase Open Delta

A 3 phase open delta is a specific electrical configuration used to connect three-phase power systems. In this arrangement, two transformers are connected in a triangular (delta) formation, with one corner left open or unconnected. The open delta configuration is an alternative to the more common closed delta and wye connections.

The open delta connection is typically employed when there is a need to supply three-phase power but with reduced transformer capacity compared to a full three-transformer setup. This configuration is often used as a cost-effective solution in situations where the power demand is not expected to reach the maximum capacity of a fully-equipped three-phase system.

How the 3 Phase Open Delta Connection Works

In a 3 phase open delta connection, two transformers are connected in series, forming a triangular shape with one corner left open. Each transformer has a primary winding and a secondary winding. The primary windings are connected to the three-phase power source, while the secondary windings are connected to the load.

The transformers in an open delta configuration are typically labeled as the main transformer and the teaser transformer. The main transformer is connected between two phases of the power source, while the teaser transformer is connected between one of these phases and the third phase.

The voltage across the secondary winding of each transformer is equal to the line-to-line voltage of the primary side divided by the turns ratio of the transformer. The open corner of the delta formation results in a phase shift between the voltages of the two transformers, creating a three-phase output.

It’s important to note that the capacity of an open delta system is limited to 57.7% of the total capacity of the two transformers. This is because the teaser transformer only carries the current of one phase, while the main transformer carries the current of two phases. As a result, the teaser transformer is typically rated at 50% of the main transformer’s capacity to balance the load across both transformers.

Features of 3 Phase Open Delta

Reduced Transformer Usage

One of the most notable features of the 3 phase open delta connection is its ability to operate with only two transformers instead of the typical three required in a closed delta or wye configuration. By eliminating the need for a third transformer, the open delta connection can reduce initial installation costs and minimize the space required for the transformers.

Power Capacity

In an open delta connection, the total power capacity is reduced compared to a closed delta or wye configuration. The open delta connection can handle approximately 58% of the total power capacity of a closed delta or wye system using three transformers of the same rating. This means that the open delta connection is suitable for applications where the load demand is not expected to exceed this capacity.

Voltage Balance

The 3 phase open delta connection maintains a balanced voltage across all three phases, even with the absence of a third transformer. This voltage balance is achieved through the proper sizing and connection of the two transformers. By maintaining a balanced voltage, the open delta connection ensures that the connected loads receive a stable and consistent power supply.

Backup Functionality

Another feature of the 3 phase open delta connection is its inherent backup functionality. In the event of a failure or maintenance requirement for one of the transformers, the remaining transformer can continue to supply power to the connected loads. Although the total power capacity will be reduced, the open delta connection provides a level of redundancy that can minimize downtime and ensure continuous operation in critical applications.

Advantages of 3 Phase Open Delta

Cost-Effective Solution

One of the primary advantages of the 3 phase open delta connection is its cost-effectiveness. By utilizing only two transformers instead of three, as required in a closed delta or wye configuration, the open delta connection reduces equipment costs. This makes it an economical choice for applications where the load demand does not necessitate the full capacity of three transformers.

Reduced Footprint and Weight

The elimination of one transformer in the open delta configuration results in a smaller footprint and reduced overall weight of the system. This is particularly beneficial in situations where space is limited or where the installation site has weight restrictions. The compact nature of the open delta connection makes it easier to accommodate in various industrial and commercial settings.

Disadvantages of 3 Phase Open Delta

Reduced Power Capacity

One notable disadvantage of the 3 phase open delta connection is its reduced power capacity compared to a closed delta or wye configuration. With only two transformers, the open delta connection has approximately 57.7% of the total power capacity of an equivalent closed delta or wye system.

Potential Voltage Imbalance

The open delta connection is more susceptible to voltage imbalances compared to closed delta or wye configurations. The absence of the third transformer can lead to uneven voltage distribution across the phases, particularly if the load is not balanced. This voltage imbalance can cause issues with sensitive equipment and may require additional measures, such as load balancing or the use of voltage regulators, to mitigate the effects.

Limited Fault Current Capability

Another disadvantage of the open delta connection is its limited fault current capability. In the event of a fault, such as a short circuit, the open delta configuration may not be able to provide sufficient fault current to promptly operate protective devices like fuses or circuit breakers.

Applications of 3 Phase Open Delta

Rural Electrification

The 3 phase open delta connection is commonly used in rural electrification projects where the load demand is relatively low and the cost of infrastructure is a significant consideration. The reduced transformer count and associated cost savings make the open delta configuration an attractive option for providing three-phase power to remote areas with limited electrical infrastructure.

Temporary Power Supply

Open delta connections are often employed in temporary power supply scenarios, such as construction sites or outdoor events. The compact size and reduced equipment requirements of the open delta configuration make it easier to set up and dismantle temporary power systems. The cost-effectiveness of the open delta connection is also advantageous in these short-term applications.

Backup Power Systems

In some industries, such as manufacturing or data centers, the open delta connection is used as part of a backup power system. The ability of the open delta configuration to continue operating with a reduced capacity during transformer failure provides a level of redundancy and ensures a minimum level of power availability until the primary power source is restored or the faulty transformer is replaced.